3. Relieve resin tank pressure:
A. Remove control valve cover.
B. Press down on the top of the drive gear to disengage
the cam gear.
C. With the cam gear disengaged, rotate the cam gear
counterclockwise to the Backwash position.
Check that there is no water flow through the drain line
before performing service or preventative maintenance.
4. Disconnect the water conditioner from the plumbing.
5. Using needle-nose pliers, remove the outer gland and the
turbine wheel from the outlet of the valve. Generally it
will not be necessary to remove the inner gland.
6. Clean all iron deposits and/or debris off the turbine
wheel. Excessive accumulation of iron may be removed
from the components with a solution of sodium
hydrosulfite (or sodium bisulfite). Rinse the components
thoroughly in clean water after using the iron removal
solution.
7. Flush accumulated iron deposits and/or debris from the
inside of the valve outlet.
8. Reinstall the turbine wheel into the outlet side of the
valve, being certain that the turbine wheel shaft is
carefully seated into the bearing of the inner gland.
9. Carefully reinstall the outer gland into the outlet side of
the valve. Check turbine rotation.
10. Reconnect the water conditioner to the plumbing and
follow Initial Start-up, page 7.
11. Open a downstream faucet (conditioned water) and
check to be certain that the flow indicator (colon) is
blinking.
Figure 13
Disinfection of Water Conditioners
The construction materials of the water conditioning system
do not support bacterial growth or contaminate the water
supply. However, we recommend that the conditioner be
disinfected after installation and before the conditioner can
become fouled with organic matter during normal usage or
with bacteria from the water supply. Periodic disinfection is
recommended for all conditioners. Use one of the following
methods of disinfection based on operating conditions, style
of conditioner, type of resin, and disinfectant available.
Sodium Hypochlorite 5.25%
Sodium Hypochlorite solutions can be used with polystyrene
resin, synthetic gel zeolite, greensand, and bentonites and re
available under trade names such as Clorox*. Adjust the
dosage if stronger commercial solutions are used.
The recommended dosage for 5.25% solutions is:
Polystyrene resin: 1.2 fluid ounces per cubic foot.
Non-resinous exchangers: 0.8 fluid ounce per cubic foot.
Complete the following steps to disinfect the conditioner:
Add the sodium hypochlorite solution to the brine well of the
brine tank. Make sure that the brine tank has water in it so the
solution is carried into the conditioner. Proceed with normal
regeneration. Refer to the Manual Regeneration section.
*Clorox is a trademark of the Clorox Co.
Inner Gland
Turbine Wheel
Outer Gland
Turbine Assembly